INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-2)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Tools/Special Tools
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Personnel Required
(2)
1.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
YES
NO
TEST OPTIONS
REASON FOR QUESTION
Go to step 2 of this fault.
2-2288
Change 2
x3. NO POWER TO ENHANCED POSITION LOCATION REPORTING SYSTEM (EPLRS)
Contact supervisor, Ehanced Position
Location Reporting System (EPLRS)
troubleshooting needs to be performed.
START
TM 9-2320-366-20-3
POSSIBLE PROBLEMS
Circuit breaker CB5 is not
tripped.
Faulty circuit breaker CB5.
Faulty digitization rack power
supply.
Faulty Enhanced
Position Location Reporting
System (EPLRS).
Is 24 VDC present at
terminal lug TL8?
If 24 VDC is not present, go to
step 2 of this fault.
If 24 VDC
is present, perform Enhanced
Position Location Reporting
System (EPLRS)
troubleshooting.