2-2287
VOLTAGE TEST
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle.
Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
(1) Remove dust boot from terminal lug TL15.
(2) Set multimeter to volts DC.
(3) Connect positive (+) probe of multimeter to
terminal lug TL15.
(4) Connect negative (-) probe of multimeter to
known good ground.
(5) Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(6) Position master power switch to off
(TM 9-2320-366-10-1).
(7) If 24 VDC is not present, replace power
cable from terminal lug TL15 to terminal
lug TL22.
(8) If 24 VDC is present, replace Power
Distribution Panel (PD2).