TM 9-2320-366-34-3
Change 2
16-499
b. Disassembly.
(1)
Remove two 90-degree fittings (1) from linear
directional control valve (2).
(2)
Remove two preformed packings (3) from 90-
degree fittings (1).
Discard preformed packings.
(3)
Remove tee fitting (4) from adapter (5).
(4)
Remove adapter (5) from linear directional control
valve (2).
(5)
Remove preformed packing (6) from adapter (5).
Discard preformed packing.
(6) Remove adapter (7) from linear directional control
valve (2).
(7) Remove preformed packing (8) from adapter (7).
Discard preformed packing.
(8) Remove tee fitting (9) from linear directional control
valve (2).
(9) Remove preformed packing (10) from tee fitting (9).
Discard preformed packing.
NOTE
Mark adapters for correct alignment during
installation.