Table 2. STE/ICE-R NO-GO-Chain Tests (Contd)
STARTER CIRCUIT TESTS (Contd)
NG80
DCA
MODE
3
CHECK STARTER VOLTAGE:
• Dial 68 into TEST SELECT and press TEST.
• Engage fuel shutoff switch and crank the engine and
observe the displayed voltage.
• Is the voltage above 18.5 volts minimum?
4
STARTER NEGATIVE CABLE DROP:
• Dial 69 into TEST SELECT and press TEST.
• Engage fuel shutoff switch and crank the engine and
observe the displayed voltage.
• Is the cable drop less than the limit on the VTC?
NO
YES
• Proceed to step 5.
5
4
NO
YES
• Inspect and clean all ground cables from starter,
engine, and batteries, and check for integrity.
Repair as necessary (WP 0125 00).
• Repeat step 4.
TEST NO.
TEST
69
STARTER NEGATIVE
CABLE DROP
TEST NO.
TEST
68
STARTER MOTOR
VOLTAGE
• Replace starter motor (WP 0091 00).
NOTE
After completing repair, rerun the GO-Chain
tests to verify that the problem is fixed and
that no other problems exist.


Back to Top