REMOVAL
1.
Remove two clamps (14) and ducts (1) from diverter (12).
2.
Disconnect defroster control cable (7) from shaft lever (10).
3.
Loosen screw (8) and remove defroster control cable (7) from clamp (9) and diverter (12).
4.
Remove four screws (11) and diverter (12) from mounting bracket (13).
5.
Loosen two clamps (5) and remove diverter (12), duct (6), and two clamps (5) from heater (3).
6.
Remove four screws (4) and mounting bracket (13) from firewall (2).
INSTALLATION
1.
Install mounting bracket (13) on firewall (2) with four screws (4).
2.
Install duct (6) and diverter (12) on heater (3) with two clamps (5).
3.
Install diverter (12) on mounting bracket (13) with four screws (11).
4.
Install two ducts (1) on diverter (12) with clamps (14).
5.
Insert defroster control cable (7) through clamp (9) and install on shaft lever (10).
6.
Tighten screw (8) and clamp (9).
1
~
3
5
6
7
8
9
10
11
12
13
4
0241 00-2
TM 9-2320-386-24-1-1
0241 00
PERSONNEL HOT WATER HEATER DIVERTER REPLACEMENT (Contd)
END OF WORK PACKAGE