1 2-46.
STEACE-R TEST PROCEDURES
(Cont’d)
I
PRESSURE (PSI) 0 TO 1,000 TEST #50
‘Description:
Pre-Test Procedures:
This procedure
measures pressure in the 0
to 1,000 PSIG range. Test requires the use
of the TK adapters
and transducers.
Run confidence
test.
Typical
Applications:
Oil pressure
Control
Functions:
01,02,03.04,
06
Test Procedure:
Possible
Error Messages:
1. Attach connector
Pi of cable W4 to J2 TK or
J3 TK.
2. Install blue-striped
pressure transducer
where
pressure is to be measured.
Attach connector
P2 of cable W4 to transducer.
3. Set TEST SELECT switch to 50. Press and
hold TEST button until CAL appears on
display.
4. Release TEST button and watt for offset value
to appear on display. If offset is within -150 to
150, proceed.
If not, go to DCA
Troubleshooting
Procedure.
5. Energize system.
6. Press and release TEST button.
7. Observe displayed value.
E005 Offset not performed.
E002 Transducer
not connected.