TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 546 of 1205

TM
9-2320-387-24-l
1 2-46.
STEACE-R TEST PROCEDURES
(Cont’d)
STARTER CURRENT AVERAGE
TEST #71
Description:
This procedure
measures the average starter
current in the 0 - 1,000 amps range. Test
requires DCA hookup only.
Typical
Applications:
Control
Functions:
Check starter current.
01, 02,03.04,06
Test Procedure:
1. Disconnect fuel solenoid wire 54A to prevent
starting.
2. Set TEST SELECT switch to 71.
3. Press and hold TEST button until CAL
appears on display.
4. Release TEST button and wait for offset
value to appear on display. If offset is within
-150 to 150, proceed. ff not, go to DCA
Troubleshooting
Procedure.
5. Press and release TEST button.
6. Crank engine.
7. Observe the displayed starter Current.
Pre-Test Procedures:
Run confidence
test.
Possible
Error Messages:
E005
Offset not performed.
2-500


Back to Top