TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 552 of 1205

TM 9-2320-387-24-l
1 2-46.
STUlCE-R
TEST PROCEDURES
(Cont’d)
DC VOLTAGE 0 TO 45 VOLTS
TEST #89
Description:
Pm-Test Procedures:
This procedure
measures voftage in the range of
-45 to 45 volts. The VTM is used as a DC voltmeter
with the decimal point in the correct position. This
test must be done with the component
being tested
turned on. Test requires the use of the TK adapters
and transducers.
Run confidence
test.
Typical Applications:
l
Fuel solenoid
l
Starter solenoid
l
Alternator output
l
Any DC voltage measurement
Test Procedure:
1. Connect test probe cable W2. Attach Pl to J4.
2. Connect the desired test leads to P2.
3. Set TEST SELECT switch to 89.
4. Short leads together.
Press and hold TEST
button until CAL appears on display.
5. Release TEST button and wait for offset value to
appear on display.
6. If offset is within -6.8 to 6.8, proceed.
If not, go
to DCA Troubleshooting
Procedure.
7. Press and release TEST button. Observe
displayed
value.
Control Functions:
01,02, 03, 04. 06
Possible Error Messages:
E005
Offset not performed.
2-506


Back to Top