TM g-2320-387-24-1
1 2-46.
STUICE-R
TEST PROCEDURES
(Cont’dl
I
BATTERY CURRENT
TEST #80
Description:
This procedure
measures current to or from
the battery. Test requires DCA hookup only.
Typical
Applications:
Control
Functions:
Evaluate
batteries in Cl engines.
01(02,03,04
Test Procedure:
1. Set TEST SELECT switch to 80.
2. Press and hold TEST button until CAL
appears on display.
3. Release TEST button and wait for offset
value to appear on display. If offset is within
-150 to 150, proceed. If not, go to DCA
Troubleshooting
Procedure.
4. Press and release TEST button.
5. Observe displayed
value (amps).
Pre-Test Procedures:
Run confidence test.
Possible
Error Messages:
EOOS Offset not performed.
2-505