TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 544 of 1205

TM 9-2320-387-24-l
1 2-46.
STEIICE-R
TEST PROCEDURES
(Cont’d)
STARTER NEGATIVE CABLE VOLTAGE DROP TEST #69
Description:
Pre-Test Procedures:
This procedure
measures the voltage drop
on the starter path. A high voltage (>2V)
indicates excessive
ground path resistance.
Test requires DCA hookup only.
Run confidence
test.
Typical Applications:
Check starter negative cable voltage drop.
Test Procedure:
1. Disconnect fuel solenoid wire 64A to prevent
starting.
2. Set TEST SELECT switch to 69.
3. Press and release TEST button.
4. Crank the engine and observe the displayed
vottage.
Control Functions:
01.02,
03,04,
06
Possible Error Messages:
None.
2-498


Back to Top