TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 224 of 1616

TM 9-2320-440-13&P
0025-8
0025
RACK LOCKS ENGAGED INDICATOR LIGHT(S) DO NOT OPERATE PROPERLY (CONTINUED)
THAAD0437
NOTE
Perform Step 9 only if MRP rack locks are disengaged.
MRP present proximity switches must be active to engage MRP rack locks.
If MRP rack
is not loaded, activate both MRP present proximity switches by placing metal objects over
proximity switches while engaging MRP rack locks.
Step 9.
If MRP is not loaded, place metal objects over MRP present proximity switches. Then
start engine (
and engage MRP rack locks (WP 0012). Shut off
engine (
Check if both MRP rack locks are fully engaged.
If both MRP rack locks are not fully engaged, troubleshoot MRP Locks Do
Not Engage (WP 0040).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)
TM 9-2320-347-10)


Back to Top