TM 9-2320-440-13&P
0025-2
0025
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
RACK LOCKS ENGAGED INDICATOR LIGHT(S) DO NOT OPERATE PROPERLY
THAAD0419
NOTE
This work package includes the procedures required to troubleshoot the LHS cab control
MRP LOADED indicator light, MRP control station RACK LOCKS ENGAGED indicator
light, and MRP control station RACK LOCKS ENGAGED blackout indicator light.
Step 1.
Check if LHS cab control MRP LOADED indicator light illuminates for five seconds
when the engine start switch is turned to the ON position (
If MRP LOADED indicator light does not illuminate, troubleshoot LHS Cab
Control Fails Self Test or No VIM Heart Beat Indication (WP 0030).
TM 9-2320-347-10)