TM 9-2320-440-13&P
0024-6
0024
NO HIGH IDLE DURING MRP ELEVATION OPERATION OVER 5 DEGREES (CONTINUED)
THAAD0539
WARNING
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment or
severe burns or electrical shock to personnel.
NOTE
Relay 10 has to be partially removed to perform Step 8.
Step 8.
Install relay 10 (TM 9-2320-325-14&P). Turn engine start switch ON
(
Select N (neutral) on transmission range selector
(
Position LHS cab control mode select switch to MRP position
(WP 0007). With jumperwires installed in THAAD chassis harness MUJB connector per
Step 1, check for continuity from ECU vehicle/selector harness relay 10 connector,
terminal 30 to a known good ground, when deck elevation controls are operated
(WP 0007).
If there is no continuity, replace relay 10 (TM 9-2320-325-14&P).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)
TM 9-2320-347-10)