TM 9-2320-440-13&P
0025-3
0025
RACK LOCKS ENGAGED INDICATOR LIGHT(S) DO NOT OPERATE PROPERLY (CONTINUED)
THAAD0420
NOTE
MRP control station lamp test will test the RACK LOCKS ENGAGED, RACK LOCKS
ENGAGED blackout indicator lights, AIR BAG PRESSURE DEPLETED and AIR BAG
PRESSURE DEPLETED blackout indicators light.
Step 2.
Perform MRP control station lamp test by selecting LAMP TEST switch (WP 0004).
a.
If RACK LOCKS ENGAGED, RACK LOCKS ENGAGED blackout
indicator lights, AIR BAG PRESSURE DEPLETED and AIR BAG
PRESSURE DEPLETED blackout indicator lights do not illuminate,
troubleshoot MRP Control Station Indicator Lights Do Not Operate
During Lamp Test (WP 0036).
b.
If only the RACK LOCKS ENGAGED indicator light does not illuminate,
go to Step 3.
c.
If only the RACK LOCKS ENGAGED blackout indicator light does not
illuminate, go to Step 6.
d.
If RACK LOCKS ENGAGED and RACK LOCKS ENGAGED blackout
indicator lights illuminate, go to Step 9.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION