TM 9-2320-440-13&P
0117-1
0117
FIELD LEVEL MAINTENANCE
GENERATOR FUEL SUPPLY LINE REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WARNING
The fuels in this generator set are highly explosive. Do not smoke or use open
flame when performing maintenance. Flames and explosion could result in serious
injury or death to personnel.
NOTE
•
Generator must be shut down and cooled prior to removal of fuel supply line.
•
Tag and mark fuel lines prior to removal to ensure proper installation.
•
Cap and plug fuel lines and fittings upon removal.
•
Remove cable ties as required.
1.
Remove fuel supply line (1) from fitting (2).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
THAAD0373
Tools and Special Tools
Set, Cap and Plug (WP 0183, Item 17)
Tool Kit, General Mechanic’s: Automotive
(WP 0183, Item 25)
Materials/Parts
Locknut, (4), (WP 0184, Item 26)
Tags, Identification (WP 0186, Item 32)
Ties, Cable, Plastic (WP 0186, Item 34)
Personnel Required
MOS 63B Wheeled vehicle mechanic
References
None
Equipment Conditions
Engine OFF (
Wheels chocked (
TM 9-2320-347-10)
TM 9-2320-347-10)