TM 9-2320-440-13&P
0118-2
0118
REMOVAL
WARNING
The THAAD hydraulic system operates at oil pressure up to 3,250 psi (22,409 kPa).
Never disconnect any hydraulic line or fitting without first dropping pressure to
zero. Failure to comply may result in serious injury or death to personnel.
NOTE
•
Position drain pan under hydraulic lines and fittings being removed.
•
Tag and mark hydraulic lines prior to removal to ensure proper installation.
•
Cap and plug hydraulic lines upon removal.
•
Perform steps (1) through (4) to remove hydraulic filter assembly and bracket.
•
Perform step (5) for hydraulic filter disassembly, cleaning/inspection, and assembly.
1.
Remove two hoses (1 and 2) from two fittings (3 and 4).
THAAD0216