CLEANING
WARNING
Compressed air used for cleaning purposes shall not exceed 30 psi (207 kPa). Use
only with effective chip guarding and personal protective equipment (goggles/
shield, gloves, etc.), or injury to personnel may result.
1.
Clean hydraulic reservoir (5), three nipples (2, 4, and 7), and elbow (3) with solvent cleaning compound and
clean with lint-free rags.
2.
Dry hydraulic reservoir (5), nipples (2, 4, and 7), and elbow (3) with compressed air.
3.
Clean two strainers (1 and 6) with solvent cleaning compound. Inspect for tears and large pieces of
contamination. Dry with compressed air.
END OF TASK
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Coat threads on both ends of nipple (7) with pipe thread sealing compound.
2.
Install nipple (7) on hydraulic reservoir (5).
3.
Install strainer (6) on nipple (7).
THAAD0390