TM 9-2320-440-13&P
0124-3/(4 blank)
0124
INSTALLATION
1.
Lightly lubricate two preformed packings (15) with clean oil and install preformed packings (15) on sight
glass (14).
2.
Install sight glass (14) on hydraulic reservoir (4) with two locknuts (13). Tighten locknuts (13) to 50 to 55 lb-ft
(68 to 75 N•m).
3.
Install gasket (12) and top plate (9) on hydraulic reservoir (4) with 33 screws (11) and locknuts (10).
4.
Install bracket (8) on top plate (9) with three screws (7) and locknuts (6).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5.
Install gasket (5) and retaining plate (2) on hydraulic reservoir (4) with screws (3).
6.
Install breather filler cap (1) on retaining plate (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install hydraulic reservoir filter and housing (WP 0121).
END OF TASK
END OF WORK PACKAGE
THAAD0439