TM 9-2330-326-14&P
3-9
Table 3-1. Operator/Crew PMCS (Cont.)
ITEM
NO.
INTERVAL
ITEM TO CHECK/
SERVICE
PROCEDURE
EQUIPMENT NOT
READY/AVAILABLE IF:
WARNING
Wear
protective
goggles
if
you
are
under semitrailer and need to operate
drain
valves.
Avoid
the
air
stream.
Failure to do so could result in personal
injury.
15
Before
Air Reservoir
Tanks
a.
Make sure drain valves do not leak air.
Drain valves leak air.
b.
Inspect air tanks for damage, loose fittings,
missing hardware, and any evidence of air
leakage.
Any air leaks are present
or hardware is missing.
c.
Inspect drain valve pull cables for a frayed
or broken condition.
16
Before
Stowage Box
and Door
Open and close door, make sure hinge does
not bind, and all mounting/securing hardware is
tight and present. Make sure drain holes are not
blocked. Insure jack is secure and door seal is
in
good
condition.
Keep
box
clean
and
serviceable.
Hardware loose or
missing.
17
Before
Twist Locks
CAUTION
Make sure there is no debris in ISO
container
lock
slots
that
would
prevent
twistlock
engagement
and
positive locking
Check to make sure there is no debris
in
the
lock
pocket
that
would
interfere with lock operation. Make
sure twist locks (all) operate freely
and do not bind.
Twist locks are required
for mission.