ELECTRICAL PARTS
Inspect all wiring harnesses for broken, chafed, or burned wiring. Inspect all terminal connectors for loose
connections and broken parts.
END OF TASK
METAL PARTS
Visually inspect all castings and weldments for cracks. Parts that carry a great load should receive magnetic particle
inspection. Critical nonferrous parts may be inspected with fluorescent penetrant.
END OF TASK
END OF WORK PACKAGE