INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open flame and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
CAUTION
Use sealing compound sparingly and only on threads. Do not apply sealing compound on
hose connections. Damage to equipment may result.
1.
Apply sealing compound on threads of fitting (Figure 7, Item 1).
7
8
1
6
5
2
3
4
Figure 7.
Brake Power Regulator Valve Installation.
2.
Install fitting (Figure 7, Item 1) on valve (Figure 7, Item 6).
3.
Install female connector (Figure 7, Item 8) on fitting (Figure 7, Item 1).
4.
Apply sealing compound on the inside threads of fitting (Figure 7, Item 7).
5.
Install fitting (Figure 7, Item 7) on female connector (Figure 7, Item 8).
6.
Apply sealing compound to threads of fitting (Figure 7, Item 5).
7.
Install fitting (Figure 7, Item 5) on valve (Figure 7, Item 6).
8.
Apply sealing compound on threads of fitting (Figure 7, Item 2).
9.
Install fitting (Figure 7, Item 2) on fitting (Figure 7, Item 5).
10.
Apply sealing compound on threads of fitting (Figure 7, Item 3).
11.
Install fitting (Figure 7, Item 3) on fitting (Figure 7, Item 2).
12.
Apply sealing compound on the inside threads of fitting (Figure 7, Item 4).
13.
Install fitting (Figure 7, Item 4) on fitting (Figure 7, Item 3).
14.
Install two nuts (Figure 8, Item 3) and lockwasher (Figure 8, Item 2) on fitting (Figure 8, Item 4).