REMOVAL - Continued
3.
Remove fitting (Figure 2, Item 4) from bulkhead coupler (Figure 2, Item 3).
4.
Remove air line 2229 (Figure 2, Item 10) from fitting (Figure 2, Item 9).
5.
Remove filter (Figure 2, Item 1) from fitting (Figure 2, Item 8).
6.
Remove fitting (Figure 2, Item 9) from filter (Figure 2, Item 1).
7.
Remove fitting (Figure 2, Item 8) from bulkhead coupler (Figure 2, Item 3).
8.
Remove nut (Figure 2, Item 2) and bulkhead coupler (Figure 2, Item 3) from bracket (Figure 2, Item 7).
END OF TASK
INSTALLATION
1.
Install bulkhead coupler (Figure 3, Item 3) on bracket (Figure 3, Item 7) with nut (Figure 3, Item 2).
3
7
8
9
10
6
5
4
2
1
Figure 3.
Drawbar Air System Quick Disconnect Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open flame and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
TM 9-2330-342-23&P
0083
0083-3