TM 9-2330-356-14
(b) Loading With a Hose. The
loading hose
from the storage facility may have a metal fitting on the
free end, and the hose may not be bonded internally. Such
a fitting is insulated and could become charged. Before
opening fill cover, connect the vehicle bonding and
grounding cable to grounding stud (fig. 2-7) on top of tank
and to some part of the permanent piping of the loading
facility.
(4)
Remove fire extinguishers and bring them to
the point of operation.
(5)
Remove padlock. Slowly open fill cover
(fig. 2-20) and insert hose far enough to keep end of hose
in contact with bottom of tank.
NOTE
The capacity Indicator gage Is located Inside
the tank near the fill cover (fig. 2-20).
(6)
Slowly begin flow, and fill tank no further
than to the bottom of the capacity indicator.
Figure 2-21. Typical Arrangement for Top Loading.
2-22