TM-9-2330-356-14

SEMITRAILER, TANK: 5000 GALLON, BULK HAUL, SELF LOAD/UNLOAD M967 AND M967A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, AUTOMOTIVE M969 AND M969A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, UNDER/OVERWING AIRCRAFT M970 AND M970A1

TECHNICAL MANUAL; OPERATOR’S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1990

  TM-9-2330-356-14 - Page 65 of 528

(7)
Capacity indicator may he adjusted as follows:
(a)
Locate the semitrailer on level ground.
(b)
Ensure that tank is empty.
(c)
Fill the tank by metering in 5000 gallons
of fuel.
(d)
Loosen the jam nut and screw the round
level indicator up or down, as required, until the fuel level
just touches the bottom of the indicator. Hold indicator
firmly and tighten the jam nut. No further adjustment
should be required.
(8)
Remove fill hose. Close and secure manhole
fill cover. Install padlock.
TM 9-2330-356-14
(9)
Drain accumulated water (para 2-13d).
(10)
Remove grounding clip from grounding stud
on top of tank. Store and cover fire extinguishers.
b.
Bottom Loading (Nonfiltered) (Fig. 2-22).
(1)
Review instructions in paragraph 2-8.
(2)
Ensure that all valves are closed.
(3)
Ground the semitrailer tank (para 2-8).
(4)
Remove cover from bottom loading connec-
tion. Connect bottom loading hose to bottom loading
connection (fig. 2-22 and 2-11 or 2-12). Have fire extin-
guishers ready.
Figure 2-22. Typical Bottom Loading Flow Diagram for All Models (M967 and M967A1 Arrangement Shown).
2-23


Back to Top