TM 9-2350-238-34-1
2-31. MAINTENANCE OF FABRIC FUEL CELL INSTALLATION AND FABRIC FUEL CEL L
FILLER BLOCKS (CONT) .
INSTALLATION (CONT )
6 6
6 7
6 8
6 9
NOT E
Steps 66 thru 68 are written and
illustrated for left fabric fuel cell ac-
cess cover but apply to both left and
right fabric fuel cell access covers.
Remove two capscrews (35) securing lef t
fabric fuel cell nut ring (34) to left fabric
fuel cell access opening (31).
Place access cover gasket (69) on access
ring. Apply sealing compound to two cap-
screws (35). Secure access cover gaske t
(69) and left fabric fuel cell nut ring (34) to
left fabric fuel cell access opening (31)
with two capscrews (35). Torque cap-
screws to 108.0 to 120.0 in.-lb (12.2 to
13.6 N-m) .
Apply sealing compound to 20 capscrews (70). Secure fuel cell access cover (71) and left
fabric fuel cell nut ring (34) to hull with 20 new lockwashers (72) and 20 capscrews (70).
Torque all capscrews to 120.0 to 130.0 in.-lb (13.6 to 14.7 N-m).
Install fan well cover. Refer to TM 9-2350-238-20-1 .
TES T
1
2
Remove fuel filler neck cap. Turn ca p
vent valve, on underside of cap, to
CLOSED position. Install fuel filler neck
cap and tighten .
Remove plug from coolant heater fue l
intake line (1). Install nipple (2) into fuel
intake line. Connect hose (3) to nippl e
(2).
2-6 6