REFUEL/DEFUEL OPERATION - Continued
Table 1.
Flow Regulator Settings.
FLOW
REGULATOR
SETTING
APPROX FLOW
OUTPUT AT
REGULATOR (gpm)
AVERAGE TORQUE OUTPUT (ft-lb)
APPROX FUEL
TRANSFER
RATE (gpm)
1 INCH BOLT AT
5 SECS
1 INCH BOLT AT
10 SECS
0
6.3
Do not use
Do not use
36
0.50
6.2
Do not use
Do not use
35.5
1.00
6.0
Do not use
Do not use
35
1.50
5.8
Do not use
Do not use
34
2.00
5.5
Do not use
Do not use
33.5
2.50
5.1
Do not use
Do not use
33
3.00
4.5
Do not use
Do not use
29
3.25
4.1
940
Do not use
26.5
3.50
3.9
800
1000
24
3.75
3.5
620
770
21
4.00
3.2
490
580
18.5
4.25
2.8
360
480
16
4.50
2.4
305
450
14
5.00
1.7
9
5.50
1.1
3
6.00 through 10.00
0
0