CONNECTING EXOTHERMIC CUTTER
1.
Open oxygen cylinder valve (Figure 2, Item 4).
2.
Open regulator valve (Figure 2, Item 1) slightly to remove debris, then close oxygen cylinder valve
(Figure 2, Item 4) and regulator valve.
3.
Connect oxygen hose (Figure 2, Item 2) and exothermic cutter (Figure 2, Item 3) to regulator valve
(Figure 2, Item 1).
4.
Open oxygen cylinder valve (Figure 2, Item 4) and regulator valve (Figure 2, Item 1) to between
10 and 80 psi, depending on target material and type of work being performed. See Table 1 for
recommended settings.
Figure 2.
Oxygen Cylinder and Exothermic Cutter.
TM 9-2350-256-10
0052
0052-4