TM-9-2350-256-10

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

OPERATOR'S MANUAL

OCTOBER 2014

  TM-9-2350-256-10 - Page 527 of 796

Table 1.
Operator Preventive Maintenance Checks and Services (PMCS) – Before - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
WARNING
Do not leave warning horn in override
position. Horn override will prevent warning
horn from sounding during vehicle fault and
engine fire. Failure to comply may result in
personnel death, injury, and/or damage to
equipment.
5. Ensure vehicle WARNING HORN is OFF. Press and
hold TEST switch until the STATUS LEDs begin to
cycle (5 seconds), then release. Verify that the vehicle
horn pulses 3 times then stops, all STATUS LEDs
temporarily illuminate during the lamp test cycling, no
STATUS LED remains illuminated, and the SYSTEM
ON LED does illuminate after the lamp test has
concluded.
6. Ensure two manual discharge switch covers and
seals are intact.
13
BEFORE
Portable Fire
Extinguishers
1. Check portable fire extinguisher control seals and
lockwires for damage.
Any fire extinguisher
missing. Seal or lockwire
missing or broken.
2. Check fire extinguishers mounting bracket for
missing hardware and ensure fire extinguisher can be
securely mounted in the bracket.
Fire extinguisher cannot
be securely mounted.
3. Check inspection tags for current inspection date of
cylinders.
Out-of-date inspection
tag.
Figure 16.
Portable Fire Extinguisher.
TM 9-2350-256-10
0096
0096-13


Back to Top