Table 1.
Operator Preventive Maintenance Checks and Services (PMCS) – During - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
6. Remove oil gauge rod, and verify oil level on
ENG IDLING RANGE side of oil gauge rod is within
ENG IDLING RANGE marks.
WARNING
Hot engine surfaces can ignite engine oil.
Clean oil from around oil filler tube area with
wiping rags after filling. Ensure engine oil
filler tube cap is tight and engine oil fill
access door is closed and latched. Failure
to comply may result in personnel death,
injury, and/or damage to equipment.
7. If oil level is below hash marks on ENG IDLING
RANGE side of oil gauge rod, add oil and recheck. To
add proper grade oil:
a. Pull up on engine oil filler tube cap handle and
open engine oil filler tube.
b. Insert offset funnel in oil filler tube.
c. Add oil as required using offset funnel. Refer to
Lubrication Instructions (WP 0101).
Figure 6.
Filling Procedure.
8. Close oil filler tube cap and all access doors.
TM 9-2350-256-10
0097
0097-6