Table 1.
Operator Preventive Maintenance Checks and Services (PMCS) – After - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
7
AFTER
Fixed Fire
Extinguisher
System (FFES),
If Equipped
1. Check pins for presence and ensure safety seals
are serviceable.
Missing pins or seals
damaged.
CAUTION
Excessive movement of cable assemblies
could discharge the fire extinguishers.
2. Check cable assemblies for damage.
Cable assemblies
damaged.
3. Check cylinder control heads, connecting tubes,
distribution tubes, and mounting brackets for damage
or looseness.
Any component damaged
or cannot be tightened.
Figure 2.
Fixed Fire Extinguisher System (FFES).
TM 9-2350-256-10