HYDRAULIC OIL SAMPLING
NOTE
•
For sampling instructions, refer to AOAP TB 43-0211 (WP 0131) prior to
performing Step 1.
•
For Steps 1 and 5, only perform steps needed to open and close floor access plate
(WP 0099).
1.
Open floor access plate #8 (WP 0099).
2.
Remove hydraulic reservoir filler cap (Figure 3).
3.
Insert tube and fill hydraulic fluid sampling bottle.
4.
Install hydraulic reservoir filler cap (Figure 3).
5.
Close floor access plate #8 (WP 0099).
Figure 3.
Hydraulic Reservoir Filler Cap.
TM 9-2350-256-10
0101
0101-8