LUBRICATION INTERVALS - Continued
Table 5.
Hydraulic Reservoir, Grease Points, Oil Can Points, and Hoist Winch, Main Winch,
Boom Stayline, and Tow Cable Lubricants.
COMPONENT (CAPACITY)
120°F TO -25°F (49°C TO -32°C)
Hydraulic Reservoir (95.0 gal/359.6 L)
OE/HDO-10
All Grease Points (As Required)
GAA
All Oil Can Points (As Required)
PL-S
Hoist Winch Cable (As Required)
OE/HDO
Main Winch Cable (As Required)
Boom Stayline Cables (As Required)
GRSWR
Tow Cables (As Required)
Army Oil Analysis Program (AOAP)
When AOAP analysis is available, follow the direction of the AOAP laboratory for engine oil, transmission oil, and
hydraulic fluids as prescribed by DA PAM 750-8 (WP 0131).
When AOAP analysis is not available and OE/HDO is used, change engine oil and filters at 150 hours or
1,500 miles (2,414 km) of operation or ANNUALLY, whichever comes first.
When AOAP analysis is not available and OEA-30 is used, change engine oil and filters at 150 hours or
1,500 miles (2,414 km) of operation or ANNUALLY, whichever comes first.
When AOAP analysis is not available, change transmission oil and filters at 150 hours or 1,500 miles (2,414 km)
of operation or ANNUALLY, whichever comes first.
MAIN ENGINE OIL SAMPLING
NOTE
For sampling instructions, refer to AOAP TB 43-0211 (WP 0131) prior to performing
Step 1.
1.
Remove front engine deck grilles (WP 0030).
2.
Remove protective cap from sampling valve (Figure 1).
3.
Position sample collection bottle under sampling valve (Figure 1).
TM 9-2350-256-10
0101
0101-4