TM 9-2350-260-20-1-2
ENGINE OIL COOLER FLUID PUMP CONNECTOR REPLACEMENT (2D ENGINE) (Sheet 4 of 4)
5.
Using two 1-1/2 inch wrenches, install hose (E) to
fitting (F).
6.
Using screwdriver and 3/8 inch wrench, install
clamp (G) on hose (E) if removed during
disassembly.
7.
Position new sealing washer (H) over vent hole.
8.
Using 9/16 inch wrench, install vent bolt (J)
through washer (H).
9.
Using socket and torque wrench, tighten drain
valve (K) to a minimum of 150 lb-in (17 N
•
m).
Do
not overtighten.
10.
Perform ground hop (page 5-57).
Run engine at
idle until oil temperature is in normal operating
range (TM 9-2350-260-10).
11.
Check oil level.
Add oil as required (LO
9-2350-260-12.
12.
Disconnect ground hop kit (page 5-67).
13.
Install powerplant (page 5-40).
End of Task
6-157