TM 9-2350-260-20-1-2
PERSONNEL HEATER FUEL PUMP REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
1.
Using 1/2 inch wrench, install elbow (A) into pump
(B).
2.
Using 7/16 inch wrench, install elbow (C) into
pump (B).
NOTE
When installing heater pump, make
sure cable condenser bracket is
secured
with
pump
mounting
bracket.
NOTE
Be sure elbows (A) and (C) are alined
with the chalk marks on the pump.
3.
Mount condenser bracket and fuel pump (B) to plate.
Using fingers, install two screws (D) and flat washers (E).
4.
Install two new lockwashers (F) and nuts (G) to
other side of mounting plate.
5.
Using socket, tighten screws (D) while holding nuts
(G) with 7/16 inch open end wrench.
6.
Using 5/8 inch wrench, connect and tighten nut (H)
to connect hose (J) to 45
°
elbow.
7.
Using 9/16 inch wrench, connect and tighten nut
(K) of tube (L) to 90
°
elbow.
8.
Plug electrical connector (M) to harness (N).
9.
Operate personnel heater (TM 9-2350-260-10).
End of Task
TA148144
7-69