TM-9-2350-260-20-1-2

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 2 OF 4, CHAPTERS 5 THRU 9

  TM-9-2350-260-20-1-2 - Page 388 of 772

TM 9-2350-260-20-1-2
AIR CLEANER (ALUMINUM AND SIDE LOADING) BLOWER FAN POWER LEAD REPLACEMENT (Sheet 2 of 4)
NOTE
Aluminum
air
cleaner
shown.
Procedure for side loading air cleaner
is similar.
2.
Push shell (B) back away from contact (C).
3.
Using pliers, remove washer (D) from lead (E).
4.
Remove shell (B).
5.
Using pliers, loosen and back off nut (F).
6.
Pull lead (E) out of adapter (G).
When lead is pulled, washers (H), (J), and gasket (K) will also be pulled out.
7.
Remove lead (E).
Remove washers (H) and (J), gasket (K), and nut (F) from lead (E).
Throw gasket away.
8.
Inspect all remaining parts for defects or deterioration.
Replace as necessary.
Go on to Sheet 3
TA148194
7-119