TM 9-2350-260-20-1-2
AIR CLEANER FILTER ELEMENT CLEANING OR REPLACEMENT (TOP LOADING) (Sheet 5 of 5)
4.
Make sure that filter element (B) is properly
positioned so that door arms (D) engage locking
pins on sides of filter element.
5.
Close door (E), and using socket, install screws
(F).
6.
Using socket, tighten screws (F) to secure door
(E).
NOTE
Step 7 applies to armored air
cleaners only.
7.
Press indicator reset button (G) to make sure
indicator shows clear window.
End of Task
TA148190
7-115