TM 9-2350-260-20-1-2
AIR CLEANER (ALUMINUM AND SIDE LOADING) BLOWER FAN GROUND LEAD REPLACEMENT (Sheet 1 of 2)
TOOLS:
7/16 in. combination box and open end wrench
SUPPLIES:
Lockwasher (MS35338-33) (2 required)
REFERENCE:
TM 9-2350-260-10
PRELIMINARY PROCEDURES:
Remove air cleaner cover and gasket (page 7-131, steps 1 thru 3)
Make sure MASTER CONTROL switch is OFF (TM 9-2350-260-10)
NOTE
Aluminum air cleaner shown.
Procedure for side
loading air cleaner is similar.
REMOVAL:
1.
Disconnect two connectors (A) from blower leads
(B).
2.
Using wrench, remove screw (C) and lockwashers
(D) securing ground lead (E) terminal to boss (F).
Throw lockwashers away.
3.
Remove ground lead (E).
Go on to Sheet 2
TA148198
7-123