TM 9-2350-260-20-1-2
AIR CLEANER (ALUMINUM AND SIDE LOADING) BLOWER FAN REPLACEMENT (Sheet 5 of 6)
INSTALLATION:
1.
Position pad (A) and bracket (B) in housing.
2.
Coat threads of two screws (C) with sealer (Item
53, Appendix D), and install two screws (C, new
lockwashers (D), and flat washers (E) to secure
bracket (B).
3.
Using 9/16 inch socket, tighten screws (C).
4.
Connect jumper lead (F) to longer blower lead.
5.
Position blower (G) into bracket (B).
6.
Position bracket (B) around blower (G) and install two screws (H), new lockwashers (J), and flat washers (K) to
secure band.
7.
Using 1/2 inch socket, tighten screws (H).
8.
Connect short electrical lead (L) of blower to ground lead.
9.
Connect hose (M) to inlet port of blower (G).
10.
Slide hose clamp (N) over hose (M) and inlet port of blower (G).
11.
Using screwdriver, tighten nut of clamp (N).
Go on to Sheet 6
TA148204