TM 9-2350-260-20-1-2
AIR CLEANER (ARMORED) BLOWER FAN HOSE REPLACEMENT (Sheet 1 of 1)
TOOLS:
Flat-tip screwdriver
SUPPLIES:
Silicone compound (Item 32, Appendix D)
PRELIMINARY PROCEDURE:
Remove air cleaner cover and gasket (page 7-149, steps 1 thru 4)
REMOVAL:
1.
Using screwdriver, loosen clamps (A).
2.
Slide clamps (A) onto hose (B).
3.
Remove hose (B) from blower fan (C) and housing
(D).
4.
Inspect hose (B) and clamps (A).
Replace as
necessary.
INSTALLATION:
1.
Position clamps (A) onto hose (B).
2.
Coat inside diameter of hose ends with silicone
compound (Item 32, Appendix D) and install hose
(B) to blower fan (C) and housing (D).
3.
Slide clamps (A) to ends of hose.
Using screwdriver, tighten clamps (A).
4.
Install air cleaner cover and gasket (page 7-150, steps 3 thru 7).
End of Task
TA148213
7-138