TM 9-2350-280-201-2
AIR CLEANER (ARMORED) BLOWER FAN GROUND LEAD REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Connect two connectors (A) to blower leads (W).
2.
Install screw (C) and two new lockwashers (D) to secure ground lead (E) terminal to boss (F).
3.
Using socket, tighten screw (C).
4.
Install air cleaner cover and gasket (page 7-150, steps 3 thru 7).
5.
Check operation of blower (TM 9-2350-260-10).
End of Task
TA148215