TM 9-2350-260-20-1-2
AIR CLEANER (ARMORED) BLOWER COVER AND GASKET REPLACEMENT (Sheet 2 of 3)
REMOVAL:
1.
Using socket, remove ten screws and lockwashers
(A) securing cover (B).
Throw lockwashers away.
2.
Place cover (B) on top of housing (C).
3.
Disconnect four electrical leads from two circuit
breakers (D) mounted to underside of cover (B).
4.
Remove cover (B) and gasket (E).
Throw gasket
away.
5.
Using screwdriver, remove four screws and lockwasher (F) securing two circuit breakers to cover (B).
Throw
lockwashers away.
Go on to Sheet 3
TA148224