TM 9-2350-260-20-1-2
AIR CLEANER (ARMORED) BLOWER FAN REPLACEMENT (Sheet 2 of 7)
REMOVAL:
1.
Using socket, remove ten screws and lockwashers
(A) securing cover (B).
Throw lockwashers away.
2.
Lift cover (B) from opening and place onto top of
housing (C).
3.
Disconnect four electrical leads from two circuit
breakers (D) mounted to underside of cover (B).
4.
Remove cover (B) and gasket (E).
Throw gasket
away.
NOTE
There are two blower fans in each air cleaner.
Each blower fan is removed in the
same way.
5.
Using screwdriver, loosen clamp (F) securing hose (G) to inlet of blower fan (H).
Slide clamp onto hose.
6.
Remove hose (G) from inlet of blower fan (H).
Go on to Sheet 3
TA148217
7-142