TM 9-2350-260-20-1-2
AIR CLEANER (ARMORED) BLOWER FAN REPLACEMENT (Sheet 3 of 7)
7.
Disconnect blower fan lead (J) from ground lead
(K).
8.
Using socket and extension, remove two screws
and lockwashers (L) securing strap (M).
Throw
lockwashers away.
9.
Remove strap (M).
10.
Remove blower fan (H).
11.
Disconnect jumper lead (N) from blower fan lead.
12.
Using socket and extension, remove screw (P)
and lockwasher Q.
Throw lockwasher away.
13.
Remove support (R) and pad (S).
INSPECTION AND REPAIR:
1.
Inspect gasket (T) on housing.
If damaged or
deteriorating, replace.
Go on to Sheet 4
TA148218
7-143