TM 9-2350-260-20-1-2
AIR CLEANER (ARMORED) CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1)
TOOLS:
Cross-tip screwdriver
SUPPLIES:
Lockwasher (MS35338-41) (4 required)
REFERENCE:
TM 9-2350-260-10
PRELIMINARY PROCEDURE:
Remove air cleaner cover and gasket (page 7-149, steps 1 thru 4)
NOTE
All air cleaner circuit breakers are removed and installed the same.
REMOVAL:
1.
Using screwdriver, remove screws (A) and lockwashers (B) securing circuit breaker (C) to cover (D).
Throw
lockwashers away.
2.
Remove circuit breaker (C).
3.
Disconnect two electrical leads (circuit 415).
INSTALLATION:
1.
Position circuit breaker (C) onto cover (D).
2.
Install new lockwashers (B) and screws (A) to
secure circuit breaker (C) to cover (D).
Using
screwdriver, tighten screws (A).
3.
Connect two electrical leads (circuit 415).
4.
Install cover and gasket (D) (page 7-150, steps 3
thru 7).
5.
Check operation of blowers (TM 9-2350-260-10).
End of Task
TA148209
7-134