TM-9-2350-260-20-1-2

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 2 OF 4, CHAPTERS 5 THRU 9

  TM-9-2350-260-20-1-2 - Page 402 of 772

TM 9-2350-260-20-1-2
AIR CLEANER (ALUMINUM AND SIDE LOADING) BLOWER COVER AND GASKET REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
1.
Position two circuit breakers (A) onto cover (B).
2.
Install new lockwashers (C) and screws (D) to
secure circuit breakers (A) to cover (B).
Using
screwdriver, tighten screws (D).
3.
Position new gasket (E) on housing with sealing
compound (Item 24, Appendix D).
4.
Position cover (B) in front of housing.
5.
Connect lead with jumper from blower to each
circuit breaker (A).
6.
Connect one connector from power lead to each
circuit breaker (A).
(Power lead is the one coming
from side of housing.)
7.
Check operation of air cleaner blower fan (TM 9-
2350-260-10).
8.
Position cover (B) to housing and install 16
assembled screws (F) and fiat washers (G) to
secure cover.
9.
Using socket and wrench, tighten screws (F).
End of Task
TA148208
7-133