TM 9-2350-260-20-1-2
AIR CLEANER (ARMORED) BLOWER FAN REPLACEMENT (Sheet 6 of 7)
10.
Apply silicone compound (Item 32, Appendix D) to
inside diameter of hose end and connect hose (L)
to inlet of blower fan (F).
11.
Slide clamp (M) up over hose and inlet of blower
fan (F).
12.
Using screwdriver, tighten clamp (M).
13.
If new gasket (N) is being used, apply sealing compound (Item 24, Appendix D) to gasket and position onto
housing.
14.
Lay cover (P) (with circuit breakers facing up) on air cleaner housing.
15.
Connect four electrical leads to two circuit breakers (Q).
16.
Check operation of blower fan (TM 9-2350-260-10).
Go on to Sheet 7
TA148221
7-146