TM 9-2350-260-20-1-2
AIR CLEANER PLUG REPLACEMENT (Sheet 1 of 1)
TOOLS:
1-1/8 in. socket with 1/2 in. drive
Ratchet with 1/2 in. drive
7/16 in. combination box and open end wrench
SUPPLIES:
Sealing compound (Item 18, Appendix D)
REMOVAL:
1.
Using socket, remove plugs (A).
2.
Using wrench, remove plug (B).
3.
Inspect plug threads for damage.
Replace as necessary.
INSTALLATION:
1.
Coat threads of plugs (A) and (B) with sealer (Item 18, Appendix D) and install into air cleaner housing.
2.
Using socket, tighten plugs (A).
3.
Using wrench, tighten plug (B).
End of Task