AIR CLEANER FILTER ASSEMBLY REPAIR AND REPLACEMENT (SIDE LOADING) (Sheet 3 of 5)
INSPECTION:
1.
Inspect baffles (A) for cracks, bends, or broken out
sections.
2.
Inspect filter element (B) for holes or damaged
seal.
3.
Inspect basket (C) for breaks or dents.
4.
Replace any part that is defective.
CLEANING:
CAUTION
When shaking element, keep dust
from inside pockets of element.
Make sure all creases and seams are
free of dust, never hit element
against any surface.
1.
Grasp filter element at the sealing end and shake vigorously to shake out dust
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi.
Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves,
etc.).
2.
Use low pressure compressed air to blow out any remaining dust from each pocket by moving nozzle back and
forth.
CAUTION
Never use steam.
Thoroughly dry element before installing.
3.
If low pressure compressed air is not available, remove remaining dust by washing in warm or cold water and liquid
detergent (Item 33, Appendix D).
4.
Use a clean, damp rag and wipe out filter compartment.
Go on to Sheet 4
TA148183
7-108