TM 9-2350-260-20-1-2
AIR CLEANER DOOR REPLACEMENT (SIDE LOADING) (Sheet 2 of 2)
INSPECTION AND REPAIR:
1.
Inspect gasket (A) on door (B).
If missing,
damaged, or deteriorating, replace.
2.
To replace, remove old gasket.
Using dry
cleaning solvent (Item 54, Appendix D), remove
old adhesive from mounting surface.
3.
Apply adhesive (Item 2, Appendix D) to mounting
surface and install new gasket (A).
INSTALLATION:
1.
Position door (A) to air cleaner housing.
2.
Install pin (B) to secure door (A) to housing.
If
necessary, use hammer to tap in pin (B).
3.
Using 9/16 inch socket, install two screws, new
lockwashers, and flat washers (C) to lock door (A)
to air cleaner housing.
4.
Install air cleaner (page 7-90).
End of Task
TA148177
7-102