TM 9-2350-260-20-1-2
AIR CLEANER FILTER ASSEMBLY REPAIR AND REPLACEMENT (SIDE LOADING) (Sheet 1 of 5)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
7-106
Disassembly
7-107
Cleaning and Inspection
7-108
Assembly
7-109
Installation
7-109
TOOLS:
9/16 in. socket with 1/2 in. drive
Ratchet with 1/2 in. drive
Slip joint pliers
SUPPLIES:
Low pressure air system
Liquid detergent (Item 33, Appendix D)
Rags (Item 65, Appendix D)
Lockwasher (MS35333-38) (2 required)
NOTE
Two types of side loading air
cleaners are found on M60 tanks.
If
your tank has type (A), start with step
1.
If your tank has type (B), skip
steps 1 and 2, go on to step 3.
REMOVAL:
NOTE
Replacement and repair of air cleaner
filter assembly is the same for left or
right side.
Left side shown.
1.
Using 9/16 inch socket, remove two screws,
lockwashers, and flat washers (C) securing door
(D).
Throw lockwashers away.
2.
Open door (D) and go to step 5.
3.
Using 9/16 inch socket, remove screw and flat
washer (E) securing handle (F).
4.
Using handle (F), open door (G.
Go on to Sheet 2
TA148181
7-106